3.4 Rear Panel connections
The Transmitter Controller has several types of connections on the rear panel of the 
unit. The following will describe each type and what it is used for. See illustration 
3-8 for location of each connector. Refer to Section 2.6 illustrations 2-7 and 2-8 for 
detailed descriptions of each applicable remote control connector.
3.4.1 DB-25
There are six (three, dual vertically stacked) DB-25 female connectors on the back of 
the Transmitter Controller. PA1 and PA2 are what is used to connect to the DB-25 
remote I/O on the back of each PA using the supplied DB-25 Male-to-Male cables. 
The connectors labled PA3, PA4, and PA5 are not used for the FM4000.
The last connector labled I/O Port A is used for the Remote Interface and has the final 
output metering information as well as the system controls for power control and high 
voltage control. See illustration 2-7 on page 2-7 for a detailed description of what 
each pin is used for.
3.4.2 DB-37
There are two (one, dual vertically stacked) DB-37 female connectors on the back 
of the Transmitter Controller. Port B is used for the Remote interface and has all the 
metering channels found on both PA1 and PA2 routed to this connector. 
Port C is not used on the FM4000. See illustration 2-8 on page 2-8 for a detailed 
description of what each pin is used for.
3.4.3 DB-9
There is one DB-9 female connector and one DB-9 male connector (vertically 
stacked) on the back of the Transmitter Controller. The port labled Directional 
Coupler is used to connect to the directional coupler mounted at the output of the 
combiner. It's primary function is to bring into the controller the forward and 
reverse power information that the controller uses to display on the front panel 
meter. It's secondary function is to provide a supply voltage to the temperature 
sensor located inside the connector shell of the cable that connects to the 
directional coupler for cabinet temperature reading available on I/O port A. It also 
provides fan voltage as well for cooling the coupler. The port labled power control 
is not used in the FM4000.
Illustration 3-8 Rear panel connections